To carry out laboratory services for TOC analysis, Hydrocarbon extraxtion, chromatography columns, Pyrolysis Rock Eval, vitrinite Reflectance & maceral composition .In addition, there are other activities in this lab such as:
-
-
Kerogen / solution
-
Carbon isotop analysis
-
Latroscan analysis
-
For sample test such as:
-
- Sample Preparation
- Source Rock Screnning analysis
- Source Rock Follow up
1. Sample Preparation :
-
-
GC-101 Registration of samples
-
GC-102 Washing of samples
-
GC-103 Washing of sample, where organic mud additives have been used
-
GC-104 Washing samples with OBM
-
GC-105 Lithology Description
-
GC-106 Hand-Picking of separate Lithologies for Screening Analysis (1-2mm)
-
GC-107 Surcharge For Picking Lithologies from cutting <1 mm
-
GC-108 Hand Picking of cutting for latroscan analysis
-
GC-109 Hand Picking of cutting for Extraction analysis
-
GC-110 Isolation of Kerogen from Sources Rock Sample
-
GC-111 Preparation of slides/ mounting for vitrinite Reflectance Meansurements
-
2. Sources Rocks screnning Analysis :
-
- GC- 201 Hydrocarbon Headspace Gas
- GC- 202 Hydrocarbon in Cutting Gas (Occluded Gas)
- GC- 203 Total Organic Carbon (TOC)
- GC- 204 Total Carbon Content (TC)
- GC- 205 Carbonate Content
- GC- 206 Sulphur Content
- GC- 207 Rock-Eval 6
3. Sources Rock Follow up Analysis :
-
-
GC- 301 Detailed C4-C7 Hydrocarbon Determination
-
GC- 302 Thermal Extraction
-
GC- 303 Pyrolsis GC
-
GC- 304 Extraction of Organic Matter by Ultrasonic Method
-
GC- 305 Extraction of Organic Matter by Soxhlet Method
-
GC- 306 Separation of Asphaltenes from Soluble Organic Matter
-
GC-307 Separation of EOM by Gravitational Column Chromatography
-
GC- 308 Separation EOM by HPLC
-
GC- 309 Iatroscan analysis of extracts
-
GC- 310 Capabillary GC Saturated Hydrocarbon Fraction
-
GC- 311 Capabillary GC Aromatic Hydrocarbon Fraction (FID only)
-
GC- 312 Kerogen Typing by Microscopy (Including Kerogen Isolation)
-
GC- 313 Kerogen maturation by TAI/SCI
-
GC- 314 Vitrinite Reflectance on whole Rock
-
GC- 315 Vitrinite Reflectance on Kerogen concentrates
-
GC- 316 Elemental analysis (C,H,O,N,S and Ash)
-
GC- 317 Biomarker analysis by GCMS on saturated fraction (Selected Ion Monitoring/SIM)
-
GC- 318 Biomarker analysis by GCMS on aromatic (SIM)
-
GC- 319 Biomarker analysis by GCMS of EOM (SIM)
-
GC- 320 Full Scan GCMS Analysis
-
GC- 321 Carbon Isotope Analysis of Individual EOM and Kerogen
-
For sample test, this lab is supported by equipment suck as: GC, GC-MS, termis 1,2,3, D basin monollys Rock Eval 6 and other supporting lab equipment.
GC GC-MS
Termis 1,2,3 D Rockeval-6
monollys